Cisco NX-OS data centre lab 8 of 15
VXLAN EVPN on two leaves
Stretch a VLAN between two Nexus leaves over a plain routed network. OSPF gives you the underlay, iBGP EVPN the control plane, and VXLAN carries the frames. Then add an anycast gateway and an L3 VNI, so a tenant routes between subnets inside the fabric.
Run this lab
It needs Standard: its 6 nodes are set to 8 vCPU and 14,336 MB in total.
In your workspace: Shared, then Cisco Nexus NX-OS data centre guided labs, then 08 - VXLAN EVPN on two leaves
- Level
- Advanced
- Time
- About 90 minutes
- Nodes need
- 8 vCPU, 14,336 MB
- Smallest plan
- Standard
The scenario
Tenant Calder Freight has servers in two rows of hall 3, and they must share a subnet. The rows are joined by routed links through R1, which knows nothing about VXLAN and shouldn't have to. You'll build the overlay on N1 and N2. OSPF is already up between the two leaves and R1, and all interfaces in the path use an MTU of 9000, so VXLAN's extra 50 bytes fit.
| Item | N1 | N2 |
|---|---|---|
| Loopback0, the VTEP address | 10.255.0.1 | 10.255.0.2 |
| Host ports | H1 on Ethernet1/6, VLAN 10 | H2 on Ethernet1/6, VLAN 10. H3 on Ethernet1/7, VLAN 20 |
| Segment | VNI | Subnet and gateway | Where |
|---|---|---|---|
| VLAN 10 SERVERS | 10010 | 10.10.10.0/24, .1 | Both leaves |
| VLAN 20 BACKUP | none | 10.20.20.0/24, .1 | N2 only |
| VLAN 500 | 50001, VRF RED's L3 VNI | none | Both leaves |
iBGP AS 65000 between the loopbacks. Anycast gateway MAC 001c.7300.0001. Hosts: H1 10.10.10.11, H2 10.10.10.12, H3 10.20.20.13.
What you’ll practise
- Explain underlay, overlay, VTEP and VNI
- Build iBGP EVPN between leaf loopbacks
- Map a VLAN to a VNI and bring up nve1 with BGP ingress replication
- Read route types 2 and 3 and follow a MAC address through the control plane
- Add an anycast gateway and an L3 VNI for symmetric routing
The tasks
- Start the lab
- The overlay's control plane
- Stretch VLAN 10
- Read the control plane
- Anycast gateway and an L3 VNI
The Lab Tasks pane has the scenario, these tasks, the checks to run, hints and the full solution.
Topology and devices
The network as it opens in EVE-NG, drawn from the lab’s own canvas, and the image each node runs.
Every link, as text
- N1
e1to R1Gi0/0 - N2
e1to R1Gi0/1 - N1
e6to H1eth0 - N2
e6to H2eth0 - N2
e7to H3eth0
| Node | Device | Image in Add Node | Set to |
|---|---|---|---|
| N1 | Cisco Nexus 9000v | nxosv9k-9300v-9.3.10 | 2 vCPU, 6,144 MB |
| N2 | Cisco Nexus 9000v | nxosv9k-9300v-9.3.10 | 2 vCPU, 6,144 MB |
| R1 | Cisco IOSv | vios-adventerprisek9-m.SPA.159-3.M6 | 1 vCPU, 512 MB |
| H1 | Alpine Linux | clbalpinebase-alpine-base-3-20-3 | 1 vCPU, 512 MB |
| H2 | Alpine Linux | clbalpinebase-alpine-base-3-20-3 | 1 vCPU, 512 MB |
| H3 | Alpine Linux | clbalpinebase-alpine-base-3-20-3 | 1 vCPU, 512 MB |
How to open this lab
Sign in to your workspace at
lab.cloudlabbox.com.In File Manager, open Shared, then the folder
Cisco Nexus NX-OS data centre guided labs.Open
08 - VXLAN EVPN on two leavesand start its nodes, then open Lab Tasks for the scenario and the steps.
The lab is read-only. You can start the nodes and configure the devices, but changes to the topology can’t be saved. To change it, rebuild it in your own folder.