Cisco Catalyst SD-WAN CLI lab 5 of 14
Control policy - hub and spoke
Turn the default full mesh into hub and spoke with a centralised control policy on the vSmart, and prove that spoke-to-spoke traffic now goes through the data centre.
Run this lab
It needs Standard: its 8 nodes are set to 8 vCPU and 6,656 MB in total.
In your workspace: Shared, then Cisco Catalyst SD-WAN CLI guided labs, then 05 - Control policy - hub and spoke
- Level
- Advanced
- Time
- About 75 minutes
- Nodes need
- 8 vCPU, 6,656 MB
- Smallest plan
- Standard
The scenario
Meridian's security team wants every branch-to-branch flow to pass the data-centre firewall. Today's overlay is a full mesh: Manchester and Leeds talk directly. You turn it into hub and spoke with a centralised control policy, written once on the vSmart, without touching a single WAN edge.
| Node | System IP | Site | INET (ge0/0) | LAN, VPN 10 (ge0/1) |
|---|---|---|---|---|
| vBond | 10.255.0.1 | 1000 | 198.51.100.1 | |
| vSmart | 10.255.0.2 | 1000 | 198.51.100.2 | |
| DC1 (hub) | 10.255.0.10 | 10 | 198.51.100.10 | 10.10.10.1/24 |
| BR1 (spoke) | 10.255.0.11 | 11 | 198.51.100.11 | 10.11.10.1/24 |
| BR2 (spoke) | 10.255.0.12 | 12 | 198.51.100.12 | 10.12.10.1/24 |
| H3, H1, H2 | 10.10.10.10, 10.11.10.10, 10.12.10.10, all fixed |
What this course leaves out. There is no SD-WAN Manager (vManage) in any of these labs. A virtual edge can't join the Manager's inventory without a signed device list from Cisco, which these labs don't have. So you won't see the Manager's GUI, dashboards, templates, Policy Builder or zero-touch onboarding. You work at the CLI of the controllers and edges, with a private lab CA and device lists typed by hand. In production you'd build this policy in the Manager's Policy Builder and activate it there. Here you write it on the vSmart CLI. The hosts have fixed addresses set at boot, because the DHCP server on these vEdge images can lock up the edge at start-up.
What you’ll practise
- Read the default full mesh
- Write a control policy that filters TLOCs and rewrites next hops
- Prove the new topology with BFD, routes and traceroute
The tasks
- Start the lab
- See the full mesh
- Plan the policy
- Write and apply the policy
- Prove the new topology
The Lab Tasks pane has the scenario, these tasks, the checks to run, hints and the full solution.
Topology and devices
The network as it opens in EVE-NG, drawn from the lab’s own canvas, and the image each node runs.
Every link, as text
- vBond
ge0/0to INET (network) - vSmart
eth0to INET (network) - DC1
G0/0to INET (network) - BR1
G0/0to INET (network) - BR2
G0/0to INET (network) - DC1
G0/1to H3eth0 - BR1
G0/1to H1eth0 - BR2
G0/1to H2eth0
| Node | Device | Image in Add Node | Set to |
|---|---|---|---|
| vBond | Cisco vBond | vtbond-20.12.2 | 1 vCPU, 1,024 MB |
| vSmart | Cisco vSmart | vtsmart-20.12.2 | 1 vCPU, 1,024 MB |
| DC1 | Cisco vEdge | vtedge-20.12.2 | 1 vCPU, 1,024 MB |
| BR1 | Cisco vEdge | vtedge-20.12.2 | 1 vCPU, 1,024 MB |
| BR2 | Cisco vEdge | vtedge-20.12.2 | 1 vCPU, 1,024 MB |
| H3 | Alpine Linux | clbalpinebase-alpine-base-3-20-3 | 1 vCPU, 512 MB |
| H1 | Alpine Linux | clbalpinebase-alpine-base-3-20-3 | 1 vCPU, 512 MB |
| H2 | Alpine Linux | clbalpinebase-alpine-base-3-20-3 | 1 vCPU, 512 MB |
How to open this lab
Sign in to your workspace at
lab.cloudlabbox.com.In File Manager, open Shared, then the folder
Cisco Catalyst SD-WAN CLI guided labs.Open
05 - Control policy - hub and spokeand start its nodes, then open Lab Tasks for the scenario and the steps.
The lab is read-only. You can start the nodes and configure the devices, but changes to the topology can’t be saved. To change it, rebuild it in your own folder.
More Cisco Catalyst SD-WAN CLI labs
All Cisco Catalyst SD-WAN CLI labs
CloudLabBox is independent of Cisco. The lab follows exam topics and isn’t vendor training material; vendor names identify the exams and the images in the workspace.