Cisco Firepower FTD and FMC in EVE-NG

Threat Defense and Management Center images are in the Add Node list of every CloudLabBox workspace, from 6.2 to 7.7, along with NGIPSv. Run the managed pair in one lab and practise access control, NAT and intrusion policy.

Choose a planCheck it in the free demo

Vendor
Cisco
In Add Node
63 images
Templates
ftd7 fmc7 firepower6 firepower
Newest
ftd7-FTD-7.7.0-89

Installed versions

Every Secure Firewall (Firepower) name in the Add Node image list, exactly as you’ll pick it.

Template ftd7

Threat Defense (FTDv) 7

6 images on this template. Newest first.

  • ftd7-FTD-7.7.0-89
  • ftd7-FTD-7.6.0-113
  • ftd7-FTD-7.4.2-172
  • ftd7-FTD-7.4.1-172
  • ftd7-FTD-7.3.1-19
  • ftd7-FTD-7.0.0-94

Template fmc7

Management Center (FMCv) 7

6 images on this template. Newest first.

  • fmc7-7.7.0-89
  • fmc7-7.6.0-113
  • fmc7-7.4.2-172
  • fmc7-7.4.1-172
  • fmc7-7.3.1-19
  • fmc7-7.0.0-94

Template firepower6

Threat Defense on the Firepower 6 template

22 images on this template. Newest first.

  • firepower6-FTD-7.3.1-19
  • firepower6-FTD-7.3.0-69
  • firepower6-FTD-7.2.2-54
  • firepower6-FTD-7.2.1-40
  • firepower6-FTD-7.2.0-82
  • firepower6-FTD-7.1.0-90
  • firepower6-FTD-7.0.4-55
  • firepower6-FTD-7.0.3-37
  • firepower6-FTD-7.0.1-84
  • firepower6-FTD-7.0.0-94
  • firepower6-FTD-6.7.0-65
  • firepower6-FTD-6.6.5-81
Show 10 older
  • firepower6-FTD-6.6.4-59
  • firepower6-FTD-6.6.3-81
  • firepower6-FTD-6.6.1-91
  • firepower6-FTD-6.6.1-90
  • firepower6-FTD-6.6.0-90
  • firepower6-FTD-6.6.0
  • firepower6-FTD-6.5.0-115
  • firepower6-FTD-6.4.0-102
  • firepower6-FTD-6.3.0-83
  • firepower6-FTD-6.2.0-362

Template firepower6

Management Center on the Firepower 6 template

22 images on this template. Newest first.

  • firepower6-FMC-7.3.1-19
  • firepower6-FMC-7.3.0-69
  • firepower6-FMC-7.2.2-54
  • firepower6-FMC-7.2.1-40
  • firepower6-FMC-7.2.0-82
  • firepower6-FMC-7.1.0-90
  • firepower6-FMC-7.0.4-55
  • firepower6-FMC-7.0.3-37
  • firepower6-FMC-7.0.1-84
  • firepower6-FMC-7.0.0-94
  • firepower6-FMC-6.7.0-65
  • firepower6-FMC-6.6.5-81
Show 10 older
  • firepower6-FMC-6.6.4-59
  • firepower6-FMC-6.6.3-81
  • firepower6-FMC-6.6.1-91
  • firepower6-FMC-6.6.1-90
  • firepower6-FMC-6.6.0-90
  • firepower6-FMC-6.6.0
  • firepower6-FMC-6.5.0-123
  • firepower6-FMC-6.4.0-102
  • firepower6-FMC-6.3.0-83
  • firepower6-FMC-6.2.0-362

Template firepower6

NGIPSv on the Firepower 6 template

6 images on this template. Newest first.

  • firepower6-NGIPS-7.0.1-84
  • firepower6-NGIPS-6.7.0-65
  • firepower6-NGIPS-6.6.1-91
  • firepower6-NGIPS-6.6.0-90.tar
  • firepower6-NGIPS-6.3.0-83
  • firepower6-NGIPS-6.2.0-362

Template firepower

Defense Center 5.4

1 image on this template.

  • firepower-DEFC-5.4.0-763

Add it to a lab

In Add Node, choose the template, then the image. The template fills in these settings; change them before you start the node.

Add Node defaults for Secure Firewall (Firepower), read from the EVE-NG templates on 28 October 2026
ImageTemplateCPURAMInterfacesConsole
Threat Defense (FTDv) 7ftd748192 MB6 interfacesVNC
Management Center (FMCv) 7fmc7428762 MB1 interfaceVNC
Threat Defense on the Firepower 6 template, Management Center on the Firepower 6 template, NGIPSv on the Firepower 6 templatefirepower648192 MB5 interfaces: eth0 / mgmnt, then G0/0 to G0/3VNC
Defense Center 5.4firepower44096 MB4 interfaces: eth0 / mgmnt, then G0/0 to G0/2VNC

EVE-NG admits a node by the CPU and RAM set on it, so a running node counts against your plan at these values. The largest of these templates starts nodes at 4 vCPU and 28,762 MB, more than the free demo’s 6 vCPU and 8 GB, so use the demo to find the image and a plan to run it.

See default usernames and passwords Read every node tip

An FTDv registered to an FMCv

Register an FTDv 7 to an FMCv 7, then build and deploy an access control policy for traffic between two Alpine Linux hosts on either side of it. You practise device registration, policy deployment and reading connection events.

  • 1×Threat Defense (FTDv) 7 ftd74 vCPU, 8192 MB
  • 1×Management Center (FMCv) 7 fmc74 vCPU, 28762 MB
  • 2×Alpine Linux clbalpinebase2 vCPU, 512 MB each

Added with these defaults, the lab uses 12 vCPU and 37.1 GB of RAM. The smallest plan that fits is Organization, with 24 vCPU and 48 GB: £10 a day, or £3 an hour On-Demand.

Choose a planGive nodes more CPU or RAM and you add that instead.

Licences are yours to bring

Threat Defense and Management Center use Cisco Smart Licensing. Management Center has a time-limited evaluation mode, and subscriptions such as IPS and URL filtering need your own entitlement: CloudLabBox doesn't provide Cisco licences or subscriptions.

The images run only inside your CloudLabBox workspace; they aren’t available to download.

Questions about Secure Firewall (Firepower)

What is Cisco Secure Firewall (Firepower)?

Cisco Secure Firewall Threat Defense (FTD, formerly Firepower) is Cisco's firewall with intrusion prevention and application control, managed from Secure Firewall Management Center (FMC). Both run as virtual machines, so you can run the managed pair in one lab.

Which template do I pick for an FTD or FMC image?

Pick the template the image name starts with: ftd7 and fmc7 hold the newest 7.x images, firepower6 holds older FTD, FMC and NGIPSv images such as firepower6-FTD-7.3.1-19, and firepower holds the Defense Center 5.4 image firepower-DEFC-5.4.0-763.

What is NGIPSv?

NGIPSv is Cisco's virtual intrusion prevention sensor: Firepower inspection without FTD's firewall and routing functions, managed from Management Center. Its images, such as firepower6-NGIPS-7.0.1-84, run on the firepower6 template.

Which Secure Firewall (Firepower) images are installed?

63 images (6 Threat Defense (FTDv) 7, 6 Management Center (FMCv) 7, 22 Threat Defense on the Firepower 6 template, 22 Management Center on the Firepower 6 template, 6 NGIPSv on the Firepower 6 template, 1 Defense Center 5.4), all listed on this page exactly as Add Node shows them. The newest is ftd7-FTD-7.7.0-89.

How much CPU and RAM does a Secure Firewall (Firepower) node use?

When you add one, the ftd7 template adds 4 vCPU and 8192 MB of RAM; the fmc7 template adds 4 vCPU and 28762 MB of RAM; the firepower6 template adds 4 vCPU and 8192 MB of RAM; the firepower template adds 4 vCPU and 4096 MB of RAM. You can change both in Add Node, and your plan counts what each running node is set to.

More images

CloudLabBox is independent of the vendors named on this page. Their names identify the images in the workspace’s Add Node list.